GENERAL LABORATORY THERMOMETERS
These all-glass Thermometers have the lines and numbers engraved on the glass tube and are adapted for
laboratories, testing small batches and miscellaneous tests. They are thoroughly annealed so as not to change with use or age. Accuracy is Guaranteed for the life of the Thermometer.
Round Front Tube / Ring Top / Yellow Back
Round Front / Button Top (For Armors) / Yellow Back
Perforated Metal Armors (Only) for "Button Top" Thermometers - Made of 3/8" O.D. Tubing with
nickeled finish.
Nickel-silver ring at top. Glass engraved tube is made with button top to fit these armors. Specify if tube is to used in armor.
ASTM THERMOMETERS / YELLOW BACK
The American Society for Testing Materials has compiled definite specifications for certain standard thermometers, giving to each a coded ASTM number as listed in their Year Book. Thermometers listed
below are made to conform to these specifications and are made with great care, being thoroughly annealed and Guaranteed Accurate so as not to change with use or age. All these thermometers are acceptable
to the National Bureau of Standards for Test Certification.
ASTM THERMOMETERS YELLOW BACK
| °F |
°C |
Description
|
|
°F |
°C |
Description
|
| 1 FY |
1 CY |
Partial Immersion |
|
71 F |
71 C |
Oil in Wax |
| 2 FY |
2 CY |
Partial Immersion |
|
|
|
|
| 3 FY |
3 CY |
Partial Immersion |
|
72 F |
72 C |
Kinematic Viscosity |
| 4 F |
- |
Partial Immersion |
|
73 F |
73 C |
Kinematic Viscosity |
| |
|
|
|
74 F |
74 C |
Kinematic Viscosity |
| 5 FY |
5 CY |
High Cloud and Pour |
|
|
|
|
| 6 F |
6 CY |
Low Cloud and Pour |
|
75 F |
- |
Anti-Freeze Freezing Pt. |
| |
|
|
|
76 F |
- |
Anti-Freeze Freezing Pt. |
| 7 FY |
7 CY |
Low Distillation |
|
|
|
|
| 8 FY |
8 CY |
High Distillation |
|
77 F |
- |
Saybolt Viscosity |
| |
|
|
|
78 F |
- |
Saybolt Viscosity |
| 9 FY |
9 CY |
Low Pensky - Martens |
|
79 F |
- |
Saybolt Viscosity |
| 10 FY |
10 CY |
High Pensky - Martens |
|
80 F |
- |
Saybolt Viscosity |
| 11 FY |
11 CY |
Pensky - Martens |
|
81 F |
- |
Saybolt Viscosity |
| |
|
|
|
|
|
|
| 12 FY |
12 CY |
Density - Wide Range |
|
82 F |
82 C |
Fuel Rating - Engine |
| |
|
|
|
83 F |
83 C |
Fuel Rating - Air |
| - |
13 CY |
Loss on Heat |
|
84 F |
84 C |
Fuel Rating - Orifice Tank |
| |
|
|
|
85 F |
85 C |
Fuel Rating - Surge |
| 14 FY |
14 CY |
Wax Melting Point |
|
86 F |
86 C |
Fuel Rating - Mix |
| |
|
|
|
87 F |
87 C |
Fuel Rating - Coolant |
| 15 FY |
15 CY |
Low Softening Point |
|
|
|
|
| 16 FY |
16 CY |
High Softening Point |
|
88 F |
88 C |
Vegetable Oil Flash |
| |
|
|
|
|
|
|
| 17 FY |
17 CY |
Saybolt Viscosity |
|
- |
89 C |
Solidification Point |
| 17 FY |
17 CY |
Saybolt Viscosity |
|
- |
90 C |
Solidification Point |
| 18 FY |
18 CY |
Saybolt Viscosity |
|
- |
91 C |
Solidification Point |
| 19 FY |
19 CY |
Saybolt Viscosity |
|
- |
92 C |
Solidification Point |
| 20 FY |
20 CY |
Saybolt Viscosity |
|
- |
93 C |
Solidification Point |
| 21 FY |
21 CY |
Saybolt Viscosity |
|
- |
94 C |
Solidification Point |
| |
|
|
|
- |
95 C |
Solidification Point |
| 22 FY |
22 CY |
Oxidation Stability |
|
- |
96 C |
Solidification Point |
| |
|
|
|
|
|
|
| - |
23 C |
Engler Viscosity |
|
88 F |
88 C |
Vegetable Oil Flash |
| - |
24 C |
Engler Viscosity |
|
|
|
|
| - |
25 C |
Engler Viscosity |
|
97 F |
97 C |
Tank |
| |
|
|
|
98 F |
98 C |
Tank |
| - |
26 C |
Stability Test of Soluble |
|
|
|
|
| - |
|
Nitro Cellulose |
|
99 F |
- |
Weathering Test |
| |
|
|
|
|
|
|
| - |
27 C |
Turpentine Distillation |
|
- |
100 C |
Solidification Point |
| |
|
|
|
- |
101 C |
Solidification Point |
| 28 F |
28 C |
Kinematic Viscosity |
|
|
|
|
| 29 F |
29 C |
Kinematic Viscosity |
|
- |
102 C |
Solvents Distillation |
| 30 F |
- |
Kinematic Viscosity |
|
- |
103 C |
Solvents Distillation |
| |
|
|
|
- |
104 C |
Solvents Distillation |
| 31 F |
- |
Reid Vapor Pressure |
|
- |
105 C |
Solvents Distillation |
| |
|
|
|
- |
106 C |
Solvents Distillation |
| 33 F |
33 C |
Low Aniline Point |
|
- |
107 C |
Solvents Distillation |
| 34 F |
34 C |
Medium Aniline Point |
|
|
|
|
| 35 F |
35 C |
Aniline Point |
|
108 F |
- |
Saybolt Viscosity |
| |
|
|
|
109 F |
- |
Saybolt Viscosity |
| - |
36 CY |
Titer Test |
|
|
|
|
| |
|
|
|
110 F |
110 C |
Kinematic Viscosity |
| - |
37 CY |
Solvents Distillation |
|
- |
111 C |
Tar Acids Distillation |
| - |
38 CY |
Solvents Distillation |
|
112 FY |
112 C |
Solidification Point of Benzene |
| - |
39 CY |
Solvents Distillation |
|
|
|
|
| - |
40 CY |
Solvents Distillation |
|
113 F |
113 C |
Softening Point - Bitumen Wide Range |
| - |
41 CY |
Solvents Distillation |
|
|
|
|
| - |
42 CY |
Solvents Distillation |
|
- |
114 C |
Aviation Fuel Freezing Point |
| |
|
|
|
|
|
|
| 43 F |
- |
Kinematic Viscosity |
|
- |
115 C |
Enclosed Scale Beckmann Differential |
| 44 FY |
44 C |
Kinematic Viscosity |
|
|
|
|
| 45 FY |
45 C |
Kinematic Viscosity |
|
- |
116 C |
Bomb Calorimeter |
| 46 F |
46 C |
Kinematic Viscosity |
|
- |
117 C |
Bomb Calorimeter |
| 47 F |
47 C |
Kinematic Viscosity |
|
|
|
|
| 48 F |
- |
Kinematic Viscosity |
|
118 F |
118 C |
Kinematic Viscosity |
| |
|
|
|
|
|
|
| - |
49 C |
Stormer Viscosity |
|
119 F |
119 C |
Anti-Freeze Freezing Pt. |
| |
|
|
|
|
|
|
| 50 FY |
- |
Gas Calorimeter-Inlet |
|
- |
120 C |
Kinematic Viscosity |
| 51 FY |
- |
Gas Calorimeter-Outlet |
|
- |
121 C |
Kinematic Viscosity |
| |
|
|
|
|
|
|
| - |
52 C |
Butadiene Boiling Point |
|
- |
122 C |
Brookfield Viscosity |
| |
|
|
|
- |
123 C |
Brookfield Viscosity |
| - |
53 C |
Benzene Freezing Point |
|
- |
124 C |
Brookfield Viscosity |
| |
|
|
|
- |
125 C |
Brookfield Viscosity |
| 54 F |
54 C |
Congealing Point |
|
|
|
|
| |
|
|
|
126 F |
126 C |
Kinematic Viscosity |
| 56 F |
56 C |
Bomb Calorimeter |
|
- |
127 C |
Kinematic Viscosity |
| |
|
|
|
128 F |
128 C |
Kinematic Viscosity |
| 57 F |
57 C |
Tagged Closed Tester - Low Range |
|
129 F |
129 C |
Kinematic Viscosity |
| |
|
|
|
|
|
|
| 58 F |
58 C |
Tank |
|
|
|
|
| 59 F |
59 C |
Tank |
|
|
|
|
| 60 F |
60 C |
Tank |
|
|
|
|
| |
|
|
|
|
|
|
| 61 F |
61 C |
Petroleum Melting Point |
|
|
|
|
| |
|
|
|
|
|
|
| 62 F |
62 C |
|
|
|
|
|
| 63 F |
63 C |
|
|
|
|
|
| 64 F |
64 C |
|
|
|
|
|
| 65 F |
65 C |
Precision Thermometers |
|
|
|
|
| 66 F |
66 C |
& Factory Certification |
|
|
|
|
| 67 F |
67 C |
of Accuracy Tolerances |
|
|
|
|
| 68 F |
68 C |
|
|
|
|
|
| 69 F |
69 C |
|
|
|
|
|
| 70 F |
70 C |
|
|
|
|
|
| |
|
|
|
|
|
|
POCKET THERMOMETERS
5" in brass case with white-nickel finish, Reversible Cap in place of ring. Specify threaded cap which can be screwed to metal case, acting as Extension Handle.
SKEWER TYPE THERMOMETERS
Sharp-Point or Bullet-End.
HYGROMETER AND WALL THERMOMETERS
All thermometers with "Red-Reading-Mercury" lens glass tube, with easy to read wide Red column. Graduated Scale. Sturdy construction. Guaranteed accurate.
WALL, HAND, AND CUP THERMOMETERS
All thermometers with "Red-Reading-Mercury" lens glass tube, with easy to read wide Red column. Graduated Scale. Sturdy construction. Guaranteed accurate.
|